Regulated Storage Tanks (RST) Data Files
Storage Tank Details for This Facility
Facility ID | AFIN | Location Name/Address | Temp Out | AG | UG | Leak | 1998 Compl |
---|---|---|---|---|---|---|---|
60000497 | 60-00617 |
DASSAULT FALCON JET 3801 E TENTH STREET LITTLE ROCK, AR 72202 County: PULASKI |
X | X | X |
Contact Name: | PETER R. CHRISTIANSEN | Date Received: | 08/24/2007 |
Contact Title: | MGR ENV AFFAIRS | Entry Date: | 07/24/1990 |
Contact Phone: | (501) 210-0147 | Entry Clerk: | TERESA |
Location SIC: | Update Date: | 09/24/2018 | |
Location AFIN: | 60-00617 | Update Clerk: | littler |
Latitude: | 34.736629 | Amended: | Y |
Longitude: | -92.231876 | Certified Name: | ERNIE VALACHOVIC |
Aboveground: | Title: | VP IND ADMIN | |
Underground: | X | Date Signed: | 8/13/2007 |
Date Reg. Cert. Issued: | 7/17/2023 | Do not invoice, if marked: | [] |
OwnerID | Owner Name/Address | Phone |
---|---|---|
000949 | DASSAULT FALCON JET CORP. P.O. BOX 967, ADAMS FIELD LITTLE ROCK, AR 72203-0967 |
(501) 372-5254 |
County: | PULASKI | Last Date Updated: | 06/04/1998 |
Owner Type: | 1 | Entry Clerk: | TERESA |
Date Form Received: | 09/30/1988 | Update Clerk: | BATEMAN |
Date Form Entered: | 07/24/1990 |
Date Signed | Financial Assurance Mechanism | Entry Clerk | Entry Date | Update Clerk | Update Date |
---|---|---|---|---|---|
11/19/1991 | CIOU - Certificate issued, original, UST | GCRAGG | 11/19/1991 |
Invoice # | Date Billed | Owner as of Billing Date | Status | Amount/ Date Due |
Last Amount Paid/ Last Date Paid |
Last Check # | Late Fee Billed | Total Paid |
---|---|---|---|---|---|---|---|---|
TKS000704 | 07/25/1990 | FALCON JET CORPORATION | $140.00 07/25/1990 |
$140.00 07/26/1990 |
109098 | $140.00 | ||
TKS006884 | 05/18/1991 | FALCON JET CORPORATION | $140.00 06/30/1991 |
$140.00 07/23/1991 |
118190 | $140.00 | ||
TKS012665 | 05/23/1992 | FALCON JET CORPORATION | $140.00 06/30/1992 |
$140.00 06/09/1992 |
127711 | $140.00 | ||
TKS018119 | 06/01/1993 | FALCON JET CORPORATION | $190.00 06/30/1993 |
$190.00 06/11/1993 |
137060 | $190.00 | ||
TKS023836 | 06/01/1994 | FALCON JET CORPORATION | $200.00 06/30/1994 |
$200.00 08/01/1994 |
152721 | $200.00 | ||
TKS029122 | 06/01/1995 | FALCON JET CORPORATION | $200.00 07/16/1995 |
$200.00 06/05/1995 |
162553 | $200.00 | ||
TKS035912 | 05/17/1996 | FALCON JET CORPORATION | $200.00 06/30/1996 |
$200.00 06/11/1996 |
173141 | $200.00 | ||
TKS039514 | 05/16/1997 | FALCON JET CORPORATION | $200.00 06/30/1997 |
$200.00 06/17/1997 |
185491 | $200.00 | ||
TKS044582 | 05/15/1998 | FALCON JET CORPORATION | $200.00 06/30/1998 |
$200.00 06/04/1998 |
198092 | $200.00 | ||
TKS049796 | 05/14/1999 | DASSAULT FALCON JET CORP. | $200.00 06/30/1999 |
$200.00 07/26/1999 |
8309 | $200.00 | ||
TKS054550 | 05/19/2000 | DASSAULT FALCON JET CORP. | $200.00 06/30/2000 |
$200.00 06/12/2000 |
225202 | $200.00 | ||
TKS058746 | 05/18/2001 | DASSAULT FALCON JET CORP. | $200.00 07/01/2001 |
$200.00 06/12/2001 |
239068 | $200.00 | ||
TKS062678 | 05/17/2002 | DASSAULT FALCON JET CORP. | $200.00 06/30/2002 |
$200.00 06/03/2002 |
252330 | $200.00 | ||
TKS066445 | 05/09/2003 | DASSAULT FALCON JET CORP. | $200.00 06/30/2003 |
$200.00 06/09/2003 |
263517 | $200.00 | ||
TKS070193 | 05/14/2004 | DASSAULT FALCON JET CORP. | $200.00 06/30/2004 |
$200.00 06/01/2004 |
274277 | $200.00 | ||
TKS074149 | 05/16/2005 | DASSAULT FALCON JET CORP. | $200.00 06/30/2005 |
$200.00 06/06/2005 |
286161 | $200.00 | ||
TKS079279 | 05/19/2006 | DASSAULT FALCON JET CORP. | $300.00 07/03/2006 |
$300.00 06/05/2006 |
298816 | $300.00 | ||
TKS084466 | 05/08/2007 | DASSAULT FALCON JET CORP. | $300.00 06/30/2007 |
$300.00 05/29/2007 |
311313 | $300.00 | ||
TKS089671 | 05/15/2008 | DASSAULT FALCON JET CORP. | $300.00 06/30/2008 |
$300.00 06/16/2008 |
326878 | $300.00 | ||
TKS094781 | 05/11/2009 | DASSAULT FALCON JET CORP. | $300.00 06/30/2009 |
$300.00 05/26/2009 |
340807 | $300.00 | ||
TKS099912 | 05/17/2010 | DASSAULT FALCON JET CORP. | $300.00 06/30/2010 |
$300.00 06/21/2010 |
353805 | $300.00 | ||
TKS105100 | 05/17/2011 | DASSAULT FALCON JET CORP. | $300.00 06/30/2011 |
$300.00 07/07/2011 |
365151 | $300.00 | ||
TKS110640 | 05/14/2012 | DASSAULT FALCON JET CORP. | $300.00 06/30/2012 |
$300.00 05/29/2012 |
375906 | $300.00 | ||
TKS115905 | 05/15/2013 | DASSAULT FALCON JET CORP. | $300.00 06/30/2013 |
$300.00 05/28/2013 |
387462 | $300.00 | ||
TKS121067 | 05/14/2014 | DASSAULT FALCON JET CORP. | $300.00 06/30/2014 |
$300.00 05/27/2014 |
398097 | $300.00 | ||
TKS126160 | 05/06/2015 | DASSAULT FALCON JET CORP. | $300.00 06/30/2015 |
$300.00 05/26/2015 |
409292 | $300.00 | ||
TKS131381 | 05/23/2016 | DASSAULT FALCON JET CORP. | $300.00 06/30/2016 |
$300.00 06/07/2016 |
421067 | $300.00 | ||
TKS136504 | 05/16/2017 | DASSAULT FALCON JET CORP. | $300.00 06/30/2017 |
$300.00 06/06/2017 |
431666 | $300.00 | ||
TKS141516 | 05/15/2018 | DASSAULT FALCON JET CORP. | $300.00 06/30/2018 |
$300.00 05/30/2018 |
442690 | $300.00 | ||
TKS146437 | 05/14/2019 | DASSAULT FALCON JET CORP. | $300.00 06/30/2019 |
$300.00 06/03/2019 |
455083 | $300.00 | ||
TKS151396 | 05/13/2020 | DASSAULT FALCON JET CORP. | $300.00 06/30/2020 |
$300.00 06/17/2020 |
467530 | $300.00 | ||
TKS156204 | 05/10/2021 | DASSAULT FALCON JET CORP. | $300.00 06/30/2021 |
$300.00 06/11/2021 |
475473 | $300.00 | ||
TKS161054 | 05/10/2022 | DASSAULT FALCON JET CORP. | $300.00 06/30/2022 |
$300.00 06/10/2022 |
269829 | $300.00 | ||
TKS166073 | 05/10/2023 | DASSAULT FALCON JET CORP. | $300.00 06/30/2023 |
$300.00 06/01/2023 |
276194 | $300.00 |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 12000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1966 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET A FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 12000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1966 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET A FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 10000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1966 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET A FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 10000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1966 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET A FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 8000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1966 | Gasoline: | X | FRP: | |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | Unknown: | ||||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 1000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | ||
Tank Status Changed Date: | 10/01/1989 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1986 | Gasoline: | X | FRP: | X |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | Unknown: | ||||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 6000 | Update Date: | |
Update Clerk: |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | X | |
Tank Status Changed Date: | 09/01/1988 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1983 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | NON-HAZ PAINT W | Unknown: | X | ||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | X | Other Description: | Other Description: | ||
Other Description: |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 1250 | Update Date: | 05/12/2005 |
Update Clerk: | LYNDA |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | ||
Tank Status Changed Date: | 09/01/1988 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1988 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | X | ||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | CHROME WASTEH20 | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PVC |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 1250 | Update Date: | 05/12/2005 |
Update Clerk: | LYNDA |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | Permanently Out Of Use | Empty: | Steel: | ||
Tank Status Changed Date: | 09/01/1988 | Diesel: | Epoxy: | ||
Status Changed Reason: | Removed | Kerosene: | Composite: | ||
Install Date: | 01/01/1988 | Gasoline: | FRP: | ||
Site Assessment Date: | Used Oil: | Concrete: | X | ||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | ||||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | CHROME WASTEH20 | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | |||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | Auto Flow Restrictor: | |||
Auto Tank Gauging: | Internal Lining: | Auto High Level Alarm: | |||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | X | ||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | Unknown: | X | |||
SIR: | Other Description: | ||||
Unknown: | X | ||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | Vapor Monitoring: | |||
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | X | Interstitial Monitoring: | ||
Sec. Cont: | Repair Date: | Unknown: | X | ||
Unknown: | Other Description: | Other Description: | |||
Other Description: | PVC |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | X | Company License Number: | |
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 2500 | Update Date: | 08/29/2007 |
Update Clerk: | mcnair |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | In Use | Empty: | Steel: | ||
Tank Status Changed Date: | Diesel: | Epoxy: | |||
Status Changed Reason: | (Not Applicable) | Kerosene: | Composite: | ||
Install Date: | 01/01/1991 | Gasoline: | X | FRP: | X |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | X | |||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | Unknown: | ||||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | X | ||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | X | ||
Inventory Controls: | Ext. FRP: | X | Auto Flow Restrictor: | ||
Auto Tank Gauging: | X | Internal Lining: | Auto High Level Alarm: | ||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | |||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | X | Unknown: | |||
SIR: | Other Description: | ||||
Unknown: | |||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | Suction; PCV: | X | Vapor Monitoring: | ||
Galvanized Steel: | X | Suction; TCV: | Groundwater Monitoring: | ||
FRP: | X | Pressure: | Line Tightness Test: | ||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | Interstitial Monitoring: | |||
Sec. Cont: | Repair Date: | Unknown: | |||
Unknown: | Other Description: | Other Description: | NOT REQUIRED | ||
Other Description: |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | X | Tester License Number: | |
Electrical Isolation: | Install Date: | ||
Unknown: | Company License Number: | ||
Other Description: | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 10000 | Update Date: | 08/29/2007 |
Update Clerk: | mcnair |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | In Use | Empty: | Steel: | ||
Tank Status Changed Date: | Diesel: | Epoxy: | |||
Status Changed Reason: | (Not Applicable) | Kerosene: | Composite: | ||
Install Date: | 01/01/1991 | Gasoline: | FRP: | X | |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | X | |||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | X | ||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | X | Auto Flow Restrictor: | X | |
Auto Tank Gauging: | X | Internal Lining: | Auto High Level Alarm: | ||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | |||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | X | Unknown: | |||
SIR: | Other Description: | ||||
Unknown: | |||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | X | Suction; PCV: | X | Vapor Monitoring: | |
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | Interstitial Monitoring: | |||
Sec. Cont: | Repair Date: | Unknown: | |||
Unknown: | Other Description: | Other Description: | vertical check | ||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | Company License Number: | ||
Other Description: | above ground | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 20000 | Update Date: | 08/29/2007 |
Update Clerk: | mcnair |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | In Use | Empty: | Steel: | ||
Tank Status Changed Date: | Diesel: | Epoxy: | |||
Status Changed Reason: | (Not Applicable) | Kerosene: | Composite: | ||
Install Date: | 01/01/1991 | Gasoline: | FRP: | X | |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | X | |||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | X | ||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | X | Auto Flow Restrictor: | X | |
Auto Tank Gauging: | X | Internal Lining: | Auto High Level Alarm: | ||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | |||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | X | Unknown: | |||
SIR: | Other Description: | ||||
Unknown: | |||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | X | Suction; PCV: | X | Vapor Monitoring: | |
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | Interstitial Monitoring: | |||
Sec. Cont: | Repair Date: | Unknown: | |||
Unknown: | Other Description: | Other Description: | vertical check | ||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | Company License Number: | ||
Other Description: | ABOVE GROUND | Installer License Number: |
Latitude: | Entry Date: | ||
Longitude: | Entry Clerk: | ||
Capacity: | 20000 | Update Date: | 08/29/2007 |
Update Clerk: | mcnair |
Status | Substance | Tank Material | |||
---|---|---|---|---|---|
Tank Status: | In Use | Empty: | Steel: | ||
Tank Status Changed Date: | Diesel: | Epoxy: | |||
Status Changed Reason: | (Not Applicable) | Kerosene: | Composite: | ||
Install Date: | 01/01/1991 | Gasoline: | FRP: | X | |
Site Assessment Date: | Used Oil: | Concrete: | |||
Site Assessment Leak Check: | New Oil: | Interior Liner: | |||
CERCLA Name: | Hazardous: | Excavation Liner: | |||
Unknown: | Double Walled: | X | |||
Mixture Description: | Polyethylene Jacket: | ||||
Other Description: | JET FUEL | Unknown: | |||
Other: | |||||
Release Detection | Corrosion Protection | Spill & Overflow Protection | |||
---|---|---|---|---|---|
Installed: | Installed: | Installed: | |||
Manual Tank Gauging: | Ext. Asphalt Coating: | Spill Catchment Basin: | X | ||
Tank Tightness Test: | Ext. Dielectric Coating: | Auto Shutoff Valve: | |||
Inventory Controls: | Ext. FRP: | X | Auto Flow Restrictor: | X | |
Auto Tank Gauging: | X | Internal Lining: | Auto High Level Alarm: | ||
Vapor Monitoring: | Cathodic Prot. System: | Unknown: | |||
Groundwater Monitoring: | Electrical Isolation: | Other Description: | |||
Interstitial/Dbl Wall: | X | Unknown: | |||
SIR: | Other Description: | ||||
Unknown: | |||||
Other Description: |
Piping Material | Piping Type | Release Detection | |||
---|---|---|---|---|---|
Bare Steel: | X | Suction; PCV: | X | Vapor Monitoring: | |
Galvanized Steel: | Suction; TCV: | Groundwater Monitoring: | |||
FRP: | Pressure: | Line Tightness Test: | |||
Copper: | Gravity: | Auto Leak Detector: | |||
Dbl. Walled: | Unknown: | Interstitial Monitoring: | |||
Sec. Cont: | Repair Date: | Unknown: | |||
Unknown: | Other Description: | Other Description: | VERTICAL CHECK | ||
Other Description: | PAINTED |
Piping Corrosion Protection |
Certificate of Compliance Testing Information |
||
---|---|---|---|
Coated/Wrapped: | Date: | ||
FRP: | Company License Number: | ||
Cathodic Prot. System: | Tester License Number: | ||
Electrical Isolation: | Install Date: | ||
Unknown: | Company License Number: | ||
Other Description: | ABOVE GROUND | Installer License Number: |
No Aboveground Storage Tank Information was found in our database for this facility.
Lust ID#: | 60-0815 | Entry Date: | 01/16/2009 |
Date Notified: | 01/15/2009 | Entry Clerk: | MORGANR |
Received By: | McDuffie, Sam | Update Date: | 03/10/2009 |
Update Clerk: | smcduffie |
Leak Information Details: | |||
---|---|---|---|
Notifier Name: | BARRY WINNINGHAM | Date: | |
Address: | SOUTHERN CO. OF NLR 1201 CYPRESS |
Amount: | |
City: | NORTH LITTLE ROCK | Substance: | JetFuel, |
State: | AR | Discovery: | OTH |
Zip: | 72114 | Cause: | |
Phone: | (501) 376-6333 | Damage: | |
Comments: INTERSTIAL OF DOUBLE WALL TANK TAKING ON WATER [MORGANR 1/16/2009 2:47:24 PM]. SOUTHERN CO. OF NLR TESTED THE SYSTEM AND FOUND NO PROBLEMS WITH THE INTER TANK WALL AND THE INTERSTITAL SPACE. A RELEASE HAS BEEN DENIED. [MORGANR 2/6/2009 3:56:25 PM]. |