Facility ID AFIN Location Name/Address Temp Out AG UG Leak 1998 Compl
60000895 60-03117  GEYER SPRINGS DIAMOND SHAMROCK
8001 GEYER SPRINGS RD #470
LITTLE ROCK, AR  72209
County: PULASKI
    X
Contact Name: TAMI GREEN Date Received: 09/04/2003
Contact Title: NONE LISTED Entry Date: 01/04/1991
Contact Phone: (501) 244-5206 Entry Clerk: LYNDA
Location SIC: Update Date: 09/15/2003
Location AFIN: 60-03117 Update Clerk: BATEMAN
Latitude: Amended: Y
Longitude: Certified Name: TAMI GREEN
Aboveground: Title: NONE LISTED
Underground: X Date Signed: 9/3/2003
Date Reg. Cert. Issued: 9/18/2003 Do not invoice, if marked: []
Owner Information Summary
OwnerID Owner Name/Address Phone
006553 DIAMOND STATE OIL LLC
5101 NORTHSHORE LANE
NORTH LITTLE ROCK, AR 72118
(501) 376-4222
County: PULASKI Last Date Updated: 01/13/2021
Owner Type: 1 Entry Clerk: SUMMERS
Date Form Received: 01/11/2021 Update Clerk: fields
Date Form Entered: 10/11/1994    
Financial Assurance Information
Date Signed Financial Assurance Mechanism Entry Clerk Entry Date Update Clerk Update Date
12/06/1991 CIOU - Certificate issued, original, UST GCRAGG 12/06/1991
11/14/1995 CIOU - Certificate issued, original, UST FIELDS 11/14/1995
09/17/2003 CIOU - Certificate issued, original, UST BATEMAN 09/17/2003
Billing/Payment Information
Invoice # Date Billed Owner as of Billing Date Status Amount/
Date Due 
Last Check # Late Fee Billed
TKS002041 10/05/1990 TOTAL ROAD RUNNER, INC. $140.00
10/05/1990
$140.00
10/05/1990
14896 $140.00
TKS009773 05/18/1991 TOTAL ROAD RUNNER, INC. $140.00
06/30/1991
$140.00
08/10/1991
182287 $140.00
TKS015424 05/23/1992 TOTAL ROAD RUNNER, INC. $140.00
06/30/1992
$140.00
06/17/1992
417579 $140.00
TKS020653 06/01/1993 TOTAL ROAD RUNNER, INC. $190.00
06/30/1993
$190.00
06/23/1993
577933 $190.00
TKS026536 06/01/1994 TOTAL PETROLEUM, INC. $200.00
06/30/1994
$200.00
06/16/1994
729366 $200.00
TKS031794 06/01/1995 TOTAL PETROLEUM, INC. $200.00
07/16/1995
$200.00
06/09/1995
864648 $200.00
TKS032514 11/13/1995 TOTAL PETROLEUM, INC. $200.00
12/28/1995
$200.00
11/14/1995
PCE726 $200.00
TKS036043 05/17/1996 TOTAL PETROLEUM, INC. $200.00
06/30/1996
$200.00
06/19/1996
999659 $200.00
TKS042103 05/16/1997 TOTAL PETROLEUM, INC. $200.00
06/30/1997
$200.00
06/19/1997
1167654 $200.00
TKS047017 05/15/1998 TOTAL PETROLEUM, INC. $200.00
06/30/1998
$200.00
07/22/1998
PCE921 $200.00
TKS048250 01/13/1999 TPI PETROLEUM, INC. $200.00
02/27/1999
$200.00
02/11/1999
1401077 $200.00
TKS052371 05/14/1999 TPI PETROLEUM, INC. $200.00
06/30/1999
$200.00
06/29/1999
1538786 $200.00
TKS056900 05/19/2000 TPI PETROLEUM, INC. $200.00
06/30/2000
$200.00
06/27/2000
1101057345 $200.00
TKS061078 05/18/2001 TPI PETROLEUM, INC. $200.00
07/01/2001
$200.00
07/16/2001
1101243106 $200.00
TKS065014 05/17/2002 TPI PETROLEUM, INC. $200.00
06/30/2002
$200.00
06/10/2002
1101398261 $200.00
TKS068749 05/09/2003 TPI PETROLEUM, INC. $200.00
06/30/2003
$200.00
06/19/2003
50731999 $200.00
TKS069226 09/17/2003 DIAMOND STATE OIL CO INC $200.00
11/01/2003
$200.00
09/17/2003
019 $200.00

Underground Tank Information for Tank #1
1998 Deadline Compliance: 
Latitude:   Entry Date: 01/04/1991
Longitude:   Entry Clerk:
Capacity: 8000 Update Date: 10/27/1995
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/23/1995  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 04/01/1978 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  
Inventory Controls:  X Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:   Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:  X Suction; TCV:   Groundwater Monitoring:  
FRP:   Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:   Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date:
FRP:   Company License Number:
Cathodic Prot. System:   Tester License Number:
Electrical Isolation:   Install Date:
Unknown:  X  Company License Number:
Other Description: Installer License Number:
Underground Tank Information for Tank #2
1998 Deadline Compliance: 
Latitude:   Entry Date: 01/04/1991
Longitude:   Entry Clerk:
Capacity: 8000 Update Date: 10/27/1995
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/23/1995  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 01/01/1978 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  
Inventory Controls:  X Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:   Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:  X Suction; TCV:   Groundwater Monitoring:  
FRP:   Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:   Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date:
FRP:   Company License Number:
Cathodic Prot. System:   Tester License Number:
Electrical Isolation:   Install Date:
Unknown:  X  Company License Number:
Other Description: Installer License Number:
Underground Tank Information for Tank #3
1998 Deadline Compliance: 
Latitude:   Entry Date: 01/04/1991
Longitude:   Entry Clerk:
Capacity: 8000 Update Date: 10/27/1995
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/23/1995  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 04/01/1978 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  
Inventory Controls:  X Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:   Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:  X Suction; TCV:   Groundwater Monitoring:  
FRP:   Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:   Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date:
FRP:   Company License Number:
Cathodic Prot. System:   Tester License Number:
Electrical Isolation:   Install Date:
Unknown:  X  Company License Number:
Other Description: Installer License Number:
Underground Tank Information for Tank #4
1998 Deadline Compliance: 
Latitude:   Entry Date: 01/04/1991
Longitude:   Entry Clerk:
Capacity: 8000 Update Date: 10/27/1995
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/23/1995  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 04/01/1978 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  
Inventory Controls:  X Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:   Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:  X Vapor Monitoring:  
Galvanized Steel:  X Suction; TCV:  X Groundwater Monitoring:  
FRP:   Pressure:   Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:   Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date:
FRP:   Company License Number:
Cathodic Prot. System:   Tester License Number:
Electrical Isolation:   Install Date:
Unknown:  X  Company License Number:
Other Description: Installer License Number:
Underground Tank Information for Tank #5
1998 Deadline Compliance: 
Latitude:   Entry Date: 11/01/1995
Longitude:   Entry Clerk: FIELDS
Capacity: 12000 Update Date: 10/15/2003
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/16/2003  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 10/04/1995 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: N New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  X
Inventory Controls:   Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:  X Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:   Suction; TCV:   Groundwater Monitoring:  
FRP:  X Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:  X Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date: 10/18/1995
FRP:  X Company License Number: 000059
Cathodic Prot. System:   Tester License Number: 000059
Electrical Isolation:   Install Date: 10/18/1995
Unknown:    Company License Number: 000427
Other Description: Installer License Number: 000427
Underground Tank Information for Tank #6
1998 Deadline Compliance: 
Latitude:   Entry Date: 11/01/1995
Longitude:   Entry Clerk: FIELDS
Capacity: 8000 Update Date: 10/15/2003
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/16/2003  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 10/04/1995 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: N New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  X
Inventory Controls:   Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:  X Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:   Suction; TCV:   Groundwater Monitoring:  
FRP:  X Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:  X Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date: 10/17/1995
FRP:  X Company License Number: 000059
Cathodic Prot. System:   Tester License Number: 000059
Electrical Isolation:   Install Date: 10/18/1995
Unknown:    Company License Number: 000427
Other Description: Installer License Number: 000427
Underground Tank Information for Tank #7
1998 Deadline Compliance: 
Latitude:   Entry Date: 11/01/1995
Longitude:   Entry Clerk: FIELDS
Capacity: 6000 Update Date: 10/15/2003
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/16/2003  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 10/04/1995 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: N New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  X
Inventory Controls:   Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:  X Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:   Suction; TCV:   Groundwater Monitoring:  
FRP:  X Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:  X Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date: 10/17/1995
FRP:  X Company License Number: 000059
Cathodic Prot. System:   Tester License Number: 000059
Electrical Isolation:   Install Date: 10/18/1995
Unknown:    Company License Number: 000427
Other Description: Installer License Number: 000427
Underground Tank Information for Tank #8
1998 Deadline Compliance: 
Latitude:   Entry Date: 11/01/1995
Longitude:   Entry Clerk: FIELDS
Capacity: 6000 Update Date: 10/15/2003
    Update Clerk: MARSH
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 09/16/2003  Diesel:  X Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 10/04/1995 Gasoline:    FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: N New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  X
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  X
Inventory Controls:   Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:  X Unknown:  
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:  X  Other Description:    
Unknown:          
Other Description: SIR        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:   Suction; TCV:   Groundwater Monitoring:  
FRP:  X Pressure:  X Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  X
Dbl. Walled:  X Unknown:   Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  
Unknown:   Other Description: Other Description: SIR
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date: 10/17/1995
FRP:  X Company License Number: 000059
Cathodic Prot. System:   Tester License Number: 000059
Electrical Isolation:   Install Date: 10/18/1995
Unknown:    Company License Number: 000427
Other Description: Installer License Number: 000427

No Aboveground Storage Tank Information was found in our database for this facility.


Storage Tank Leak Information
Lust ID#: 60-0033 Entry Date:
Date Notified: 06/12/1990 Entry Clerk:
Received By: Perry, Terry Update Date: 05/10/2006
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: MITCH STROH Date: 06/11/1990
Address: ADPC&E
Amount: 150
City: LITTLE ROCK Substance: Gasoline,
State: AR Discovery: VSS
Zip: 72209 Cause:  CUSTOMER DRIVE-OFF BREAKING HOSE.
Phone: (501) 562-7444 Damage: DRAINAGE DITCH AND SOIL UNDER DISPENSER CONTAMINATED.
Comments: METHOD OF DISCOVERY: VISUAL. ELECTRICAL POWER TURNED OFF WHEN IMPACT VALVE DIDN'T WORK. FIRE DEPT. HOSED CONTAMINATION TO STORM DRAIN. ENECOTECH AND WASTE SERVICES CLEANING UP DRAINAGE DITCH. 6/12/90 TERRY PERRY, JAMES ATCHLEY AND CASEY THOMPSON, ADPC&E, INVESTIGATED SPILL AT 13:35 HOURS. AT TIME OF INVESTIGATION, THE OWNER/OPERATOR HAD NOT REPORTED THE SPILL TO THE DEPT. THE STATION MANAGER, PAM MARTIN (568-4668), STATED HER SUPERVISOR, CARL NELSON, HAD CONTACTED EPA, AND EPA OFFICIALS WERE ONSITE. EPA HAD NOT BEEN CONTACTED. STORE MANAGER AND ROAD RUNNER MAINTENANCE MAN ADVISED OF NOTIFICATION REQUIREMENTS. MIKE BROWN, ENVIRONMENTAL COORDINATOR WITH TOTAL PETROLEUM-ROAD RUNNER DIVISION, CALLED TO REPORT SPILL OF 150-174 GALLONS OF PREMIUM UNLEADED 6/12/90. ENECOTECH AND WASTE SERVICES TO CLEAN UP SPILL, REPORT TO FOLLOW. 7/02/90 REMEDIATION REPORT RECEIVED FROM ENECOTECH ON CLEANUP EFFORTS AT THE STATION (SEE FILE). NO FURTHER ACTION REQUIRED AT THIS TIME.
Storage Tank Leak Information
Lust ID#: 60-0140 Entry Date: 09/26/1994
Date Notified: 09/26/1994 Entry Clerk: BURKE
Received By: BURKE, LORI Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: MARCIE NASSIMBENI Date:
Address: P.O. BOX 973
Amount: 40
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (214) 271-7124 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: LEAK DETECTOR TRIPPED. MADE REPAIRS AND HAD SCOTT TAYLOR RETEST LINE. L.BURKE OCT 11, 1994 ON SEPTEMBER 28, 1994 I PERFORMED A LEAK DETECTION INSPECTION SEVERAL VIOLATIONS NOTED. SEE INSPECTION SUMMARY. MAIN PROBLEM SEVERAL AREAS OF CONTAMINATION NOT RELATED TO RELEASE THAT NEED TO BE ADDRESSED. PROBLEMS WITH RECEIVING SIR INFORMATION LETTER SENT OCT 04, 1994 AND LUST PACKAGE SENT SEPTEMBER 26, 1994. IRR DUE BY OCT 15 AND ISC DUE BY NOV 9 1994. 10-13-94 L.BURKE IRR WAS RECEIVED. L.BURKE 09/18/95 ISC WAS RECEIVED ON 12/22/94 HOWEVER, IT WAS NOT PROCESS BY THE INSPECTOR AT THAT TIME. ON 9/18/95, AFTER REVIEWING THE ISC REFERRAL MEMO WAS SENT TO MY SUPERVISOR. 9/27/95 FLOYD HAMM UST SYSTEM (4 TANKS) CLOSED 11/14/95 FLOYD HAMM CLOSURE REPORT REVIEWED--NFA LETTER FOR CLOSURE/LUST 60-140 WRITTEN 4/2/96 FLOYD HAMM FEES PAID, LUST/CLOSURE NFA LETTER SENT.
Storage Tank Leak Information
Lust ID#: 60-0373 Entry Date: 07/07/1999
Date Notified: 06/21/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBISON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 223-3634 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: MAY 1999, SIR INCONCLUSIVE ON SUPER UNLEADED TANK. TO INVESTIGATE 8/18/99 R. HEALEY RECEIVED COPIES OF PASSING PREM TANK AND LINE TIGHTNESS TEST. 8/20/99 R. HEALEY NFA LETTER ISSUED. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0382 Entry Date: 07/23/1999
Date Notified: 07/22/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBINSON
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL INCONCLUSIVE FOR SUPER UNLD & REG UNLD TANK FOR JUNE 1999. TO INVESTIGATE. 8/18/99 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHNESS TEST. 8/20/99 R. HEALET NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0403 Entry Date: 09/20/1999
Date Notified: 09/14/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBINSON
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 223-3634 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON SUPER UNLEADED TANK FOR AUGUST 99. TO INVESTIGATE.
Storage Tank Leak Information
Lust ID#: 60-0414 Entry Date: 10/20/1999
Date Notified: 10/15/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBINSON
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 223-3634 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED TANK FOR SEPT 1999. TO INVESTIGATE. 1/19/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS ON THIS DATE. 3/8/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0419 Entry Date: 11/22/1999
Date Notified: 11/16/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBISON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON SUPER AND UNLEADED TANKS FOR OCT. 99. TO INVESTIGATE. 1/19/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TEST ON THIS DATE. 3/8/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0421 Entry Date: 12/06/1999
Date Notified: 12/02/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: RICHARD HEALEY Date:
Address: ADEQ
8001 NATIONAL DRIVE
Amount:
City: LITTLE ROCK Substance: Unknown,
State: AR Discovery: OTH
Zip: 72209 Cause:  HOLE IN FLEX CONNECTOR PIPING NEAR SUBMERGE PUMP HOUSING.
Phone: (501) 682-0999 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: FOUND 12 INCHES OF GASOLINE IN SUPER UNLEADED SUBMERGE PUMP HOUSING. RECOVERY GASOLINE, REPAIR LINE.
Storage Tank Leak Information
Lust ID#: 60-0432 Entry Date: 01/10/2000
Date Notified: 12/27/1999 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 S ROBISON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON SUPER UNLEADED TANK FOR NOV. 1999. TO INVESTIGATE. 1/19/00 R. HEALEY RECEIVED COPIES OF TANK AND LINE TIGHTNESS TESTS ON THIS DATE. 3/8/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0444 Entry Date: 01/24/2000
Date Notified: 01/21/2000 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 S. ROBINSON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED TANK FOR DEC. 1999. TO INVESTIGATE. 2/28/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS. 3/20/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0455 Entry Date: 02/16/2000
Date Notified: 02/14/2000 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: PAULINE HOOKER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 S. ROBINSON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED TANK FOR JAN. 2000. TO INVESTIGATE. 3/8/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS. 3/20/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0467 Entry Date: 03/20/2000
Date Notified: 03/14/2000 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: JOEL MILLER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBINSON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 223-3631 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED,PLUS AND SUPER TANKS FOR FEB. 2000. TO INVESTIGATE. 4/11/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS ON THIS DATE. 6/13/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0484 Entry Date: 05/17/2000
Date Notified: 05/12/2000 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: JOEL MILLER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBISON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 832-7599 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED TANK FOR APRIL 2000. TO INVESTIGATE. 6/1/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS ON THIS DATE. 6/16/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0489 Entry Date: 06/20/2000
Date Notified: 06/15/2000 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: JOEL MILLER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
803 SOUTH ROBISON ROAD
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF FAILURE ON UNLEADED TANK FOR MAY 2000. TO INVESTIGATE. 7/17/00 R. HEALEY RECEIVED COPIES OF PASSING TANK AND LINE TIGHTNESS TESTS. 8/4/00 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0610 Entry Date: 07/10/2001
Date Notified: 06/19/2001 Entry Clerk: HEALEYR
Received By: Healey, Richard Update Date: 09/18/2007
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: JOEL MILLER Date:
Address: ULTRAMAR DIAMOND SHAMROCK
301 WESTLAWN DRIVE
Amount:
City: TEXARKANA Substance: Unknown,
State: TX Discovery: OTH
Zip: 75501 Cause:  UNKNOWN
Phone: (903) 838-8591 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: SIR CALL OF INCONCLUSIVE ON UNLEADED PLUS AND SUPER TANKS FOR MAY 2001. TO INVESTIGATE. 7/17/01 R. HEALEY RECEIVED DENIAL LETTER AND COPIES ON PASSING TANK AND LINE TIGHTNESS TESTS ON THIS DATE. 8/17/01 R. HEALEY NFA LETTER ISSUED ON THIS DATE. FILE CLOSED.
Storage Tank Leak Information
Lust ID#: 60-0747 Entry Date: 07/26/2004
Date Notified: 07/16/2004 Entry Clerk: DAVISK
Received By: Davis, Kevin Update Date: 02/13/2006
    Update Clerk: lynda
  Leak Information Details:
Notifier Name: SLA ENVIRONMENTAL SERVICES Date:
Address: 1825 SUMMIT AVE
Amount:
City: PLANO Substance: Unknown,
State: TX Discovery: OTH
Zip: 75074 Cause:  UNKNOWN
Phone: (972) 943-9923 Damage: UNKNOWN
Comments: METHOD OF DISCOVERY: PETROLEUM CONTAMINATED SOIL ENCOUNTERED DURING SUBSURFACE SITE ASSESSMENT BY SLA. NO FURTHER ACTION MEMO 11/28/2005. TECH BRANCH REVIEW SUPPORTS NFA FOR TANK CLOSURE GIVEN 10/08/2003 [routh 12/6/2005 1:13:55 PM]. [lynda 2/13/2006 1:51:35 PM].