Regulated Storage Tanks (RST) Data Files
Storage Tank Details for This Facility


Facility Information Summary
Facility ID AFIN Location Name/Address Temp Out AG UG Leak 1998 Compl
15000039 15-00170  SOUTHERN CHRISTIAN HOME
HIGHWAY 95 NORTH
MORRILTON, AR  72110
County: CONWAY
      X
Contact Name: CARROL LEE Date Received: 11/21/1988
Contact Title: MANAGER Entry Date: 11/22/1988
Contact Phone: (501) 354-2428 Entry Clerk: GLG
Location SIC: Update Date: 04/22/2002
Location AFIN: 15-00170 Update Clerk: HORTON
Latitude: Amended: Y
Longitude: Certified Name: BURL L. HURLEY
Aboveground: Title: OWNER
Underground: X Date Signed: 11/18/1988
Date Reg. Cert. Issued: Do not invoice, if marked: []
Owner Information Summary
OwnerID Owner Name/Address Phone
000793 HURLEY OIL COMPANY
120 1\2 WEST BROADWAY
MORRILTON, AR 72110
(501) 354-2248
County: CONWAY Last Date Updated:
Owner Type: 1 Entry Clerk: GLG
Date Form Received: 01/13/1989 Update Clerk:
Date Form Entered: 01/18/1989    

No Eligibility Certification Information on record for this Facility.

No Billing/Payment Information was found for this facility.


Underground Tank Information for Tank #1
1998 Deadline Compliance: 
Latitude:   Entry Date:
Longitude:   Entry Clerk:
Capacity: 1000 Update Date:
    Update Clerk:
Status Substance Tank Material
Tank Status: Permanently Out Of Use  Empty:   Steel:  X
Tank Status Changed Date: 07/01/1986  Diesel:   Epoxy:  
Status Changed Reason: Removed Kerosene:   Composite:  
Install Date: 01/01/1971 Gasoline:  X  FRP:  
Site Assessment Date: Used Oil:    Concrete:  
Site Assessment Leak Check: New Oil:   Interior Liner:  
CERCLA Name: Hazardous: Excavation Liner:  
    Unknown:    Double Walled:  
    Mixture Description: Polyethylene Jacket:  
    Other Description:   Unknown:  
        Other:  
         
Release Detection Corrosion Protection Spill & Overflow Protection
Installed: Installed:   Installed:  
Manual Tank Gauging:   Ext. Asphalt Coating:  X Spill Catchment Basin:  
Tank Tightness Test:   Ext. Dielectric Coating:   Auto Shutoff Valve:  
Inventory Controls:   Ext. FRP:   Auto Flow Restrictor:  
Auto Tank Gauging:   Internal Lining:   Auto High Level Alarm:  
Vapor Monitoring:   Cathodic Prot. System:   Unknown:  X
Groundwater Monitoring:   Electrical Isolation:   Other Description:
Interstitial/Dbl Wall:   Unknown:      
SIR:    Other Description:    
Unknown:  X        
Other Description:        
Piping Material Piping Type Release Detection
Bare Steel:   Suction; PCV:   Vapor Monitoring:  
Galvanized Steel:  X Suction; TCV:   Groundwater Monitoring:  
FRP:   Pressure:   Line Tightness Test:  
Copper:   Gravity:   Auto Leak Detector:  
Dbl. Walled:   Unknown:  X Interstitial Monitoring:  
Sec. Cont:   Repair Date: Unknown:  X
Unknown:   Other Description: Other Description:
Other Description:        
Piping
Corrosion Protection
Certificate of Compliance
Testing Information
Coated/Wrapped:   Date:
FRP:   Company License Number:
Cathodic Prot. System:   Tester License Number:
Electrical Isolation:   Install Date:
Unknown:  X  Company License Number:
Other Description: Installer License Number:

No Aboveground Storage Tank Information was found in our database for this facility.